PubTransformer

A site to transform Pubmed publications into these bibliographic reference formats: ADS, BibTeX, EndNote, ISI used by the Web of Knowledge, RIS, MEDLINE, Microsoft's Word 2007 XML.

James M Drake - Top 30 Publications

Long-term visual outcomes of craniopharyngioma in children.

Visual function is a critical factor in the diagnosis, monitoring, and prognosis of craniopharyngiomas in children. The aim of this study was to report the long-term visual outcomes in a cohort of pediatric patients with craniopharyngioma. The study design is a retrospective chart review of craniopharyngioma patients from a single tertiary-care pediatric hospital. 59 patients were included in the study. Mean age at presentation was 9.4 years old (range 0.7-18.0 years old). The most common presenting features were headache (76%), nausea/vomiting (32%), and vision loss (31%). Median follow-up was 5.2 years (range 1.0-17.2 years). During follow-up, visual decline occurred in 17 patients (29%). On Kaplan Meier survival analysis, 47% of the cases of visual decline occurred within 4 months of diagnosis, with the remaining cases occurring sporadically during follow-up (up to 8 years after diagnosis). In terms of risk factors, younger age at diagnosis, optic nerve edema at presentation, and tumor recurrence were found to have statistically significant associations with visual decline. At final follow-up, 58% of the patients had visual impairment in at least one eye but only 10% were legally blind in both eyes (visual acuity 20/200 or worse or < 20° of visual field). Vision loss is a common presenting symptom of craniopharyngiomas in children. After diagnosis, monitoring vision is important as about 30% of patients will experience significant visual decline. Long-term vision loss occurs in the majority of patients, but severe binocular visual impairment is uncommon.

Strong coupling between slow oscillations and wide fast ripples in children with epileptic spasms: Investigation of modulation index and occurrence rate.

Epileptic spasms (ES) often become drug-resistant. To reveal the electrophysiological difference between children with ES (ES+) and without ES (ES-), we compared the occurrence rate (OR) of high-frequency oscillations (HFOs) and the modulation index (MI) of coupling between slow and fast oscillations. In ES+, we hypothesized that (1) pathological HFOs are more widely distributed and (2) slow oscillations show stronger coupling with pathological HFOs than in ES-.

Diagnostic evaluation and surgical management of pediatric insular epilepsy utilizing magnetoencephalography and invasive EEG monitoring.

The diagnosis and surgical management of pediatric patients with insular epilepsy is challenging due to variable and indistinct seizure semiology arising within the insular cortex. In addition, surgical approaches are associated with potential morbidity given the regional neurosurgical and vascular anatomy. Our institutional experience in evaluation and surgical management of insular epilepsy patients is presented. Diagnostic evaluation, surgical treatment and seizures outcomes are highlighted.

Teaching Palatoplasty Using a High-Fidelity Cleft Palate Simulator.

Cleft palate repair is a challenging procedure for cleft surgeons to teach. A novel high-fidelity cleft palate simulator has been described for surgeon training. This study evaluates the simulator's effect on surgeon procedural confidence and palatoplasty knowledge among learners.

Simulating thermal effects of MR-guided focused ultrasound in cortical bone and its surrounding tissue.

Magnetic resonance-guided focused ultrasound (MRgFUS) is emerging as a treatment alternative for osteoid osteoma and painful bone metastases. This study describes a new simulation platform that predicts the distribution of heat generated by MRgFUS when applied to bone tissue.

Development and control of a magnetorheological haptic device for robot assisted surgery.

A prototype magnetorheological (MR) fluid-based actuator has been designed for tele-robotic surgical applications. This device is capable of generating forces up to 47 N, with input currents ranging from 0 to 1.5 A. We begin by outlining the physical design of the device, and then discuss a novel nonlinear model of the device's behavior. The model was developed using the Hammerstein-Wiener (H-W) nonlinear black-box technique and is intended to accurately capture the hysteresis behavior of the MR-fluid. Several experiments were conducted on the device to collect estimation and validation datasets to construct the model and assess its performance. Different estimating functions were used to construct the model, and their effectiveness is assessed based on goodness-of-fit and final-prediction-error measurements. A sigmoid network was found to have a goodness-of-fit of 95%. The model estimate was then used to tune a PID controller. Two control schemes were proposed to eliminate the hysteresis behavior present in the MR fluid device. One method uses a traditional force feedback control loop and the other is based on measuring the magnetic field using a Hall-effect sensor embedded within the device. The Hall-effect sensor scheme was found to be superior in terms of cost, simplicity and real-time control performance compared to the force control strategy.

Simulation-based Education for Endoscopic Third Ventriculostomy: A Comparison Between Virtual and Physical Training Models.

The relative educational benefits of virtual reality (VR) and physical simulation models for endoscopic third ventriculostomy (ETV) have not been evaluated "head to head."

Validity Evidence for the Neuro-Endoscopic Ventriculostomy Assessment Tool (NEVAT).

Growing demand for transparent and standardized methods for evaluating surgical competence prompted the construction of the Neuro-Endoscopic Ventriculostomy Assessment Tool (NEVAT).

Epileptogenic high-frequency oscillations skip the motor area in children with multilobar drug-resistant epilepsy.

Subtotal hemispherectomy involves the resection of multiple lobes in children with drug-resistant epilepsy, skipping the motor area (MA). We determined epileptogenicity using the occurrence rate (OR) of high-frequency oscillations (HFOs) and the modulation index (MI), demonstrating strength of coupling between HFO and slow wave. We hypothesized that epileptogenicity increased over the multiple lobes but skipped the MA.

Signal-to-noise ratio evaluation of magnetic resonance images in the presence of an ultrasonic motor.

Safe robot-assisted intervention using magnetic resonance imaging (MRI) guidance requires the precise control of assistive devices, and most currently available tools are rarely MRI-compatible. To obtain high precision, it is necessary to characterize and develop existing MRI-safe actuators for use in a high magnetic field (≥3 T). Although an ultrasonic motor (USM) is considered to be an MRI-safe actuator, and can be used in the vicinity of a high field scanner, its presence interferes with MR images. Although an MR image provides valuable information regarding the pathology of a patient's body, noise, generally of a granular type, decreases the quality of the image and jeopardizes the true evaluation of any existing pathological issues. An eddy current induced in the conductor material of the motor structure can be a source of noise when the motor is close to the isocenter of the image. We aimed to assess the effects of a USM on the signal-to-noise ratio (SNR) of MR images in a 3-T scanner. The SNR was compared for four image sequences in transverse directions for three orientations of the motor (x, y, and z) when the motor was in the "off" state. The SNR was evaluated to assess three artifact reduction methods used to minimize the motor-induced artifacts.

Infant Robotic Cleft Palate Surgery: A Feasibility Assessment Using a Realistic Cleft Palate Simulator.

A surgical robot offers enhanced precision, visualization, and access and the potential to improve outcomes in cleft palate surgery. The goal of this study was to investigate the feasibility of using the da Vinci robot for cleft palate repair in infants using a cleft palate simulator test bed.

Evaluation and Implementation of a High-Fidelity Cleft Palate Simulator.

Cleft palate repair is a challenging procedure to learn because of the delicate tissue handling required and the small confines of the infant oral cavity. As a result, cleft palate simulators have previously been described to augment cleft palate repair training. Although valuable, they lack the fidelity for this complex procedure.

Ventricular catheter entry site and not catheter tip location predicts shunt survival: a secondary analysis of 3 large pediatric hydrocephalus studies.

OBJECTIVE Accurate placement of ventricular catheters may result in prolonged shunt survival, but the best target for the hole-bearing segment of the catheter has not been rigorously defined. The goal of the study was to define a target within the ventricle with the lowest risk of shunt failure. METHODS Five catheter placement variables (ventricular catheter tip location, ventricular catheter tip environment, relationship to choroid plexus, catheter tip holes within ventricle, and crosses midline) were defined, assessed for interobserver agreement, and evaluated for their effect on shunt survival in univariate and multivariate analyses. De-identified subjects from the Shunt Design Trial, the Endoscopic Shunt Insertion Trial, and a Hydrocephalus Clinical Research Network study on ultrasound-guided catheter placement were combined (n = 858 subjects, all first-time shunt insertions, all patients < 18 years old). The first postoperative brain imaging study was used to determine ventricular catheter placement for each of the catheter placement variables. RESULTS Ventricular catheter tip location, environment, catheter tip holes within the ventricle, and crosses midline all achieved sufficient interobserver agreement (κ > 0.60). In the univariate survival analysis, however, only ventricular catheter tip location was useful in distinguishing a target within the ventricle with a survival advantage (frontal horn; log-rank, p = 0.0015). None of the other catheter placement variables yielded a significant survival advantage unless they were compared with catheter tips completely not in the ventricle. Cox regression analysis was performed, examining ventricular catheter tip location with age, etiology, surgeon, decade of surgery, and catheter entry site (anterior vs posterior). Only age (p < 0.001) and entry site (p = 0.005) were associated with shunt survival; ventricular catheter tip location was not (p = 0.37). Anterior entry site lowered the risk of shunt failure compared with posterior entry site by approximately one-third (HR 0.65, 95% CI 0.51-0.83). CONCLUSIONS This analysis failed to identify an ideal target within the ventricle for the ventricular catheter tip. Unexpectedly, the choice of an anterior versus posterior catheter entry site was more important in determining shunt survival than the location of the ventricular catheter tip within the ventricle. Entry site may represent a modifiable risk factor for shunt failure, but, due to inherent limitations in study design and previous clinical research on entry site, a randomized controlled trial is necessary before treatment recommendations can be made.

An In vivo Multi-Modal Structural Template for Neonatal Piglets Using High Angular Resolution and Population-Based Whole-Brain Tractography.

An increasing number of applications use the postnatal piglet model in neuroimaging studies, however, these are based primarily on T1 weighted image templates. There is a growing need for a multimodal structural brain template for a comprehensive depiction of the piglet brain, particularly given the growing applications of diffusion weighted imaging for characterizing tissue microstructures and white matter organization. In this study, we present the first multimodal piglet structural brain template which includes a T1 weighted image with tissue segmentation probability maps, diffusion weighted metric templates with multiple diffusivity maps, and population-based whole-brain fiber tracts for postnatal piglets. These maps provide information about the integrity of white matter that is not available in T1 images alone. The availability of this diffusion weighted metric template will contribute to the structural imaging analysis of the postnatal piglet brain, especially models that are designed for the study of white matter diseases. Furthermore, the population-based whole-brain fiber tracts permit researchers to visualize the white matter connections in the piglet brain across subjects, guiding the delineation of a specific white matter region for structural analysis where current diffusion data is lacking. Researchers are able to augment the tracts by merging tracts from their own data to the population-based fiber tracts and thus improve the confidence of the population-wise fiber distribution.

Design and validation of an MR-conditional robot for transcranial focused ultrasound surgery in infants.

Current treatment of intraventricular hemorrhage (IVH) involves cerebral shunt placement or an invasive brain surgery. Magnetic resonance-guided focused ultrasound (MRgFUS) applied to the brains of pediatric patients presents an opportunity to treat IVH in a noninvasive manner, termed "incision-less surgery." Current clinical and research focused ultrasound systems lack the capability to perform neonatal transcranial surgeries due to either range of motion or dexterity requirements. A novel robotic system is proposed to position a focused ultrasound transducer accurately above the head of a neonatal patient inside an MRI machine to deliver the therapy.

A rapid magnetic resonance acoustic radiation force imaging sequence for ultrasonic refocusing.

Magnetic resonance guided acoustic radiation force imaging (MR-ARFI) is being used to correct for aberrations induced by tissue heterogeneities when using high intensity focusing ultrasound (HIFU). A compromise between published MR-ARFI adaptive solutions is proposed to achieve efficient refocusing of the ultrasound beam in under 10 min. In addition, an ARFI sequence based on an EPI gradient echo sequence was used to simultaneously monitor displacement and temperature with a large SNR and low distortion. This study was conducted inside an Achieva 3T clinical MRI using a Philips Sonalleve MR-HIFU system to emit a 1 ms pulsed sonication with duty cycle of 2.3% at 300 Wac inside a polymer phantom. Virtual elements defined by a Hadamard array with sonication patterns composed of 6 phase steps were used to characterize 64 groups of 4 elements to find the optimal phase of the 256 elements of the transducer. The 384 sonication patterns were acquired in 580 s to identify the set of phases that maximize the displacement at the focal point. Three aberrators (neonatal skull, 8 year old skull and a checkered pattern) were added to each sonication pattern to evaluate the performance of this refocusing algorithm (n  =  4). These aberrators reduced the relative intensities to 95.3%, 69.6% and 25.5% for the neonatal skull, 8 year old skull, and checkered pattern virtual aberrators respectively. Using a 10 min refocusing algorithm, relative intensities of 101.6%, 91.3% and 93.3% were obtained. Better relative intensities of 103.9%, 94.3% and 101% were achieved using a 25 min refocusing algorithm. An average temperature increase of 4.2 °C per refocusing test was induced for the 10 min refocusing algorithm, resulting in a negligible thermal dose of 2 EM. A rapid refocusing of the beam can be achieved while keeping thermal effects to a minimum.

Endoscopic third ventriculostomy in children: prospective, multicenter results from the Hydrocephalus Clinical Research Network.

OBJECTIVE Endoscopic third ventriculostomy (ETV) is now established as a viable treatment option for a subgroup of children with hydrocephalus. Here, the authors report prospective, multicenter results from the Hydrocephalus Clinical Research Network (HCRN) to provide the most accurate determination of morbidity, complication incidence, and efficacy of ETV in children and to determine if intraoperative predictors of ETV success add substantially to preoperative predictors. METHODS All children undergoing a first ETV (without choroid plexus cauterization) at 1 of 7 HCRN centers up to June 2013 were included in the study and followed up for a minimum of 18 months. Data, including detailed intraoperative data, were prospectively collected as part of the HCRN's Core Data Project and included details of patient characteristics, ETV failure (need for repeat hydrocephalus surgery), and, in a subset of patients, postoperative complications up to the time of discharge. RESULTS Three hundred thirty-six eligible children underwent initial ETV, 18.8% of whom had undergone shunt placement prior to the ETV. The median age at ETV was 6.9 years (IQR 1.7-12.6), with 15.2% of the study cohort younger than 12 months of age. The most common etiologies were aqueductal stenosis (24.8%) and midbrain or tectal lesions (21.2%). Visible forniceal injury (16.6%) was more common than previously reported, whereas severe bleeding (1.8%), thalamic contusion (1.8%), venous injury (1.5%), hypothalamic contusion (1.5%), and major arterial injury (0.3%) were rare. The most common postoperative complications were CSF leak (4.4%), hyponatremia (3.9%), and pseudomeningocele (3.9%). New neurological deficit occurred in 1.5% cases, with 0.5% being permanent. One hundred forty-one patients had documented failure of their ETV requiring repeat hydrocephalus surgery during follow-up, 117 of them during the first 6 months postprocedure. Kaplan-Meier rates of 30-day, 90-day, 6-month, 1-year, and 2-year failure-free survival were 73.7%, 66.7%, 64.8%, 61.7%, and 57.8%, respectively. According to multivariate modeling, the preoperative ETV Success Score (ETVSS) was associated with ETV success (p < 0.001), as was the intraoperative ability to visualize a "naked" basilar artery (p = 0.023). CONCLUSIONS The authors' documented experience represents the most detailed account of ETV results in North America and provides the most accurate picture to date of ETV success and complications, based on contemporaneously collected prospective data. Serious complications with ETV are low. In addition to the ETVSS, visualization of a naked basilar artery is predictive of ETV success.

Remote MEG dipoles in focal cortical dysplasia at bottom of sulcus.

To investigate whether the magnetoencephalography (MEG) single moving dipole (SMD) method could delineate the epileptic zone of focal cortical dysplasia (FCD) at the bottom of sulcus (FCDB).

Establishing a clinical service for the treatment of osteoid osteoma using magnetic resonance-guided focused ultrasound: overview and guidelines.

Recent studies have demonstrated the effectiveness of magnetic resonance-guided focused ultrasound (MRgFUS) in the treatment of osteoid osteoma (OO), a painful, benign bone tumor. As MRgFUS is a noninvasive and radiation-free treatment, it stands to replace the current standard of care, percutaneous radiofrequency, or laser thermal ablation. Within an institution, creation of a clinical OO MRgFUS treatment program would not only provide cutting edge medical treatment at the current time but would also establish the foundation for an MRgFUS clinical service to introduce treatments currently under development into clinical practice in the future. The purpose of this document is to provide information to facilitate creation of a clinical service for MRgFUS treatment of OO by providing (1) recommendations for the multi-disciplinary management of patients and (2) guidelines regarding current best practices for MRgFUS treatment. This paper will discuss establishment of a multi-disciplinary clinic, patient accrual, inclusion/exclusion criteria, diagnosis, preoperative imaging, patient preparation, anesthesia, treatment planning, targeting and treatment execution, complication avoidance, and patient follow-up to assure safety and effectiveness.

Design and development of magnetorheological fluid-based passive actuator.

We present the design and experimental validation of a magnetorheological (MR) fluid-based passive actuator for tele-robotic bone biopsy procedures. With Finite Element Method Magnet (FEMM) software, the required uniform magnetic field circuit design was simulated. An 1100 turn 24 AWG copper wire coil wrapped around a magnetic core was used to create a magnetic field. The field strength was measured with a Hall effect sensor, and compared to the simulation. The maximum magnetic field flux produced by a constant current of 1.4 A was 0.2 T, similar to the simulation results. A series of quasi-static experiments were conducted to characterize the forces generated by the MR fluid-based actuator under various currents up to 12 N. An analytical model was developed to validate the measurements from the passive actuator.

Design optimization of neuroendoscopic continuum instruments for third ventriculostomy and tumor biopsy.

A simulation-based approach to the design of procedure-specific dexterous neuroendoscopic continuum instruments for endoscopic third ventriculostomy and tumor biopsy is proposed. Given pre-operative CT and MRI images, the algorithm returns instrument design specifications including lengths, curvatures and alternative positions for the surgical incision while respecting anatomical boundaries. This methodology proposes a novel clinically-guided geometric representation of surgical targets specific to this indication. The additional constraints imposed by the presence of surgical trocars and endoscopes are also considered. Finally, we conclude with a clinical example to demonstrate the proposed approach.

Variable ultrasound trigger delay for improved magnetic resonance acoustic radiation force imaging.

Magnetic resonance acoustic radiation force imaging (MR-ARFI) allows the quantification of microscopic displacements induced by ultrasound pulses, which are proportional to the local acoustic intensity. This study describes a new method to acquire MR-ARFI maps, which reduces the measurement noise in the quantification of displacement as well as improving its robustness in the presence of motion. Two MR-ARFI sequences were compared in this study. The first sequence 'variable MSG' involves switching the polarity of the motion sensitive gradient (MSG) between odd and even image frames. The second sequence named 'static MSG' involves a variable ultrasound trigger delay to sonicate during the first or second MSG for odd and even image frames, respectively. As previously published, the data acquired with a variable MSG required the use of reference data acquired prior to any sonication to process displacement maps. In contrary, data acquired with a static MSG were converted to displacement maps without using reference data acquired prior to the sonication. Displacement maps acquired with both sequences were compared by performing sonications for three different conditions: in a polyacrylamide phantom, in the leg muscle of a freely breathing pig and in the leg muscle of pig under apnea. The comparison of images acquired at even image frames and odd image frames indicates that the sequence with a static MSG provides a significantly better steady state (p < 0.001 based on a Student's t-test) than the images acquired with a variable MSG. In addition no reference data prior to sonication were required to process displacement maps for data acquired with a static MSG. The absence of reference data prior to sonication provided a 41% reduction of the spatial distribution of noise (p < 0.001 based on a Student's t-test) and reduced the sensitivity to motion for displacements acquired with a static MSG. No significant differences were expected and observed for thermal maps acquired with a variable MSG and a static MSG. The use of a static MSG with a variable ultrasound trigger delay improves the ARFI displacement map quality without additional acquisition time and remains compatible with the simultaneous acquisition of MR thermal maps.

A new Hydrocephalus Clinical Research Network protocol to reduce cerebrospinal fluid shunt infection.

OBJECT In a previous report by the same research group (Kestle et al., 2011), compliance with an 11-step protocol was shown to reduce CSF shunt infection at Hydrocephalus Clinical Research Network (HCRN) centers (from 8.7% to 5.7%). Antibiotic-impregnated catheters (AICs) were not part of the protocol but were used off protocol by some surgeons. The authors therefore began using a new protocol that included AICs in an effort to reduce the infection rate further. METHODS The new protocol was implemented at HCRN centers on January 1, 2012, for all shunt procedures (excluding external ventricular drains [EVDs], ventricular reservoirs, and subgaleal shunts). Procedures performed up to September 30, 2013, were included (21 months). Compliance with the protocol and outcome events up to March 30, 2014, were recorded. The definition of infection was unchanged from the authors' previous report. RESULTS A total of 1935 procedures were performed on 1670 patients at 8 HCRN centers. The overall infection rate was 6.0% (95% CI 5.1%-7.2%). Procedure-specific infection rates varied (insertion 5.0%, revision 5.4%, insertion after EVD 8.3%, and insertion after treatment of infection 12.6%). Full compliance with the protocol occurred in 77% of procedures. The infection rate was 5.0% after compliant procedures and 8.7% after noncompliant procedures (p = 0.005). The infection rate when using this new protocol (6.0%, 95% CI 5.1%-7.2%) was similar to the infection rate observed using the authors' old protocol (5.7%, 95% CI 4.6%-7.0%). CONCLUSIONS CSF shunt procedures performed in compliance with a new infection prevention protocol at HCRN centers had a lower infection rate than noncompliant procedures. Implementation of the new protocol (including AICs) was associated with a 6.0% infection rate, similar to the infection rate of 5.7% from the authors' previously reported protocol. Based on the current data, the role of AICs compared with other infection prevention measures is unclear.

Rapid eye movement sleep reveals epileptogenic spikes for resective surgery in children with generalized interictal discharges.

Epilepsy surgery can be successful in children with extensive congenital or early acquired focal or hemispheric brain lesion on magnetic resonance imaging (MRI) despite generalized interictal epileptiform discharges (IEDs). The aim of this study was to assess if rapid eye movement (REM) sleep reduced generalized IEDs and revealed lateralized IEDs to identify the epileptogenic hemisphere in children with generalized IEDs and normal/subtle changes on MRI.

Development and content validation of performance assessments for endoscopic third ventriculostomy.

This study aims to develop and establish the content validity of multiple expert rating instruments to assess performance in endoscopic third ventriculostomy (ETV), collectively called the Neuro-Endoscopic Ventriculostomy Assessment Tool (NEVAT).

Spatial relationship between fast and slow components of ictal activities and interictal epileptiform discharges in epileptic spasms.

We analyzed the spatial distribution and concordance of fast (>10Hz) and slow (<5Hz) electroencephalogram (EEG) components of ictal activities and interictal epileptiform discharges (IIED) recorded by intracranial video EEG (IVEEG) in children with epileptic spasms (ES).

Design and evaluation of a new synthetic brain simulator for endoscopic third ventriculostomy.

Endoscopic third ventriculostomy (ETV) is an effective but technically demanding procedure with significant risk. Current simulators, including human cadavers, animal models, and virtual reality systems, are expensive, relatively inaccessible, and can lack realistic sensory feedback. The purpose of this study was to construct a realistic, low-cost, reusable brain simulator for ETV and evaluate its fidelity.

Magnetoencephalography-guided resection of epileptogenic foci in children.

Resective surgery is increasingly used in the management of pediatric epilepsy. Frequently, invasive monitoring with subdural electrodes is required to adequately map the epileptogenic focus. The risks of invasive monitoring include the need for 2 operations, infection, and CSF leak. The aim of this study was to evaluate the feasibility and outcomes of resective epilepsy surgery guided by magnetoencephalography (MEG) in children who would have otherwise been candidates for electrode implantation.

Endoscopic third ventriculostomy and choroid plexus cauterization in infants with hydrocephalus: a retrospective Hydrocephalus Clinical Research Network study.

The use of endoscopic third ventriculostomy (ETV) with choroid plexus cauterization (CPC) has been advocated as an alternative to CSF shunting in infants with hydrocephalus. There are limited reports of this procedure in the North American population, however. The authors provide a retrospective review of the experience with combined ETV + CPC within the North American Hydrocephalus Clinical Research Network (HCRN).

Factors associated with ventricular catheter movement and inaccurate catheter location: post hoc analysis of the hydrocephalus clinical research network ultrasound-guided shunt placement study.

Shunt survival may improve when ventricular catheters are placed into the frontal horn or trigone of the lateral ventricle. However, techniques for accurate catheter placement have not been developed. The authors recently reported a prospective study designed to test the accuracy of catheter placement with the assistance of intraoperative ultrasound, but the results were poor (accurate placement in 59%). A major reason for the poor accurate placement rate was catheter movement that occurred between the time of the intraoperative ultrasound image and the first postoperative scan (33% of cases). The control group of non-ultrasound using surgeons also had a low rate of accurate placement (accurate placement in 49%). The authors conducted an exploratory post hoc analysis of patients in their ultrasound study to identify factors associated with either catheter movement or poor catheter placement so that improved surgical techniques for catheter insertion could be developed.