Transcatheter closure of a huge iatrogenic atrial septal defect: A case report.

Iatrogenic atrial septal defects caused by cardiac surgery are rare complications that are traditionally repaired through reoperations; unfortunately, reoperations are accompanied by high risk and trauma.

Transcatheter Retrieval of Embolized Atrial Septal Defect Occluder Device by Waist Capture Technique.

This case study describes the successful percutaneous transcatheter retrieval of an embolized Amplatzer occluder device using the "waist capture technique" in a patient with an atrial septal defect. This technique allowed for stability of the Amplatzer device, compression of the atrial discs for easier removal, prevention of further embolization, and minimal injury to vasculature during device retrieval. This novel and effective technique can be used safely for the retrieval of Amplatzer devices in the venous system.

Percutaneous Closure of Patent Foramen Ovale in Patients With Migraine: The PREMIUM Trial.

Migraine is a prevalent and disabling disorder. Patent foramen ovale (PFO) has been associated with migraine, but its role in the disorder remains poorly understood.

An Infectious Pseudoaneurysm Caused by Ventricular Septal Defect Occluder in Patent Ductus Arteriosus Closure in a Two-Year-Old Child.

We present a case of an infectious pseudoaneurysm after patent ductus arteriosus (PDA) closure with a ventricular septal defect (VSD) occluder in a two-year-old child. The aneurysm grew rapidly but was successfully removed in time and the patient survived. To our knowledge, this is the first report of an infectious pseudoaneurysm caused by VSD occluder in PDA closure.

Recurrent Strokes After Gore Septal Occluder Device Closure of Atrial Septal Defect.

We report a case of recurrent strokes in a healthy teenager after complete closure of atrial septal defect with Gore Septal Occluder (W.L. Gore and Associates, Newark, DE) device. The disk of the device produced a friction injury to the left atrial endocardium promoting thrombus formation with subsequent embolization to the brain requiring surgical intervention.

Percutaneous closure of atrial septal defect type II - a few remarks on the basis of my own experience.

Simultaneous Closure of a Left Atrial Appendage through an Atrial Septal Defect and the Atrial Septal Defect.

Left atrial appendage (LAA) occlusion can be employed as an alternative treatment to oral anticoagulation in patients with atrial fibrillation to prevent embolic events. Atrial septal defect (ASD) may be related with right heart dysfunction and allow paradoxical embolism to occur. However, occlusion of both LAA through atrial access with ostium secundum ASD and ASD in the same setting is unusual. Therefore, we report a case in which a LAA and an ASD was sequentially occluded.

Anterior Minithoracotomy: a Safe Approach for Surgical ASD Closure & ASD Device Retrieval.

Midline sternotomy is the preferred approach for device migration following transcatheter device closure of ostium secundum atrial septal defect. Results of patients operated for device migration were retrospectively reviewed after transcatheter closure of atrial septal defect.

Young Paradoxical Stroke Treated Successfully with Mechanical Thrombectomy Using Solitaire and Transcatheter Closure of Patent Foramen Oval.

Paradoxical embolization is the mechanism for patent foramen ovale (PFO)-associated cryptogenic stroke and transcatheter closure of PFO may prevent recurrent ischemic stroke. Mechanical thrombectomy is promising to treat acute ischemic stroke due to high rates of reperfusion and reduced intracranial hemorrhage complications. We report the case of a 27-year-old woman with a massive cerebral infarction but no evidence for any atherosclerosis, who received an urgent mechanical thrombectomy with a Solitaire device. In order to ascertain the etiology of stroke, transcranial Doppler (TCD) and transesophageal echocardiograph (TEE) were conducted. TCD showed severe right-to-left shunting (shower effect) after Valsalva maneuver and bubble test and TEE identified a PFO. Therefore, the patient had suffered a paradoxical stroke associated with PFO. After two weeks of the stroke onset, transcatheter PFO closure with Cardio-O-Fix occluder was also performed successfully. During 1-year of follow-up, no recurrence of stroke occurred. Our case demonstrates that mechanical thrombectomy using a Solitaire device and transcatheter PFO closure can be safely and successfully performed to treat acute paradoxical stroke and prevent its recurrence.

Increasing propensity to pursue operative closure of atrial septal defects following changes in the instructions for use of the Amplatzer Septal Occluder device: An observational study using data from the Pediatric Health Information Systems database.

Concern for device erosion following transcatheter treatment of atrial septal defects (TC-ASD) led in 2012 to a United States Food and Drug Administration panel review and changes in the instructions for use of the Amplatzer Septal Occluder (ASO) device. No studies have assessed the effect of these changes on real-world practice. To this end a multicenter observational study was performed to evaluate trends in the treatment of ASD.

Early Dislodgment and Migration of a Left Atrial Appendage Closure Device.

A 68-year-old man underwent pulmonary vein isolation with cryoballoon combined with left atrial appendage closure using a LAmbre device. The device was dislodged and embolized early after implantation with no symptoms, and it was retrieved percutaneously. An early in-hospital check of the device position after implantation is important for early recognition of any possible device-related complication.

Patent Foramen Ovale after Cryptogenic Stroke - Assessing the Evidence for Closure.

Patent Foramen Ovale Closure or Anticoagulation vs. Antiplatelets after Stroke.

Trials of patent foramen ovale (PFO) closure to prevent recurrent stroke have been inconclusive. We investigated whether patients with cryptogenic stroke and echocardiographic features representing risk of stroke would benefit from PFO closure or anticoagulation, as compared with antiplatelet therapy.

Long-Term Outcomes of Patent Foramen Ovale Closure or Medical Therapy after Stroke.

Whether closure of a patent foramen ovale reduces the risk of recurrence of ischemic stroke in patients who have had a cryptogenic ischemic stroke is unknown.

Patent Foramen Ovale Closure or Antiplatelet Therapy for Cryptogenic Stroke.

The efficacy of closure of a patent foramen ovale (PFO) in the prevention of recurrent stroke after cryptogenic stroke is uncertain. We investigated the effect of PFO closure combined with antiplatelet therapy versus antiplatelet therapy alone on the risks of recurrent stroke and new brain infarctions.

Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44-48 mm), a single Chinese cardiac center experience.

The purpose of this study was to outline the midterm follow-up results and complications in patients who underwent transthoracic device closure of an atrial septal defect (ASD) with the very large domestic occluder (44-48 mm).

Transverse Sternal Split: a Safe Mini-invasive Approach for Perventricular Device Closure of Ventricular Septal Defect.

Perventricular device closure of ventricular septal defect through midline sternotomy avoids the cardiopulmonary bypass, however, lacks the cosmetic advantage. Perventricular device closure of ventricular septal defect with transverse split sternotomy was performed to add the cosmetic advantage of mini-invasive technique.

Hemodynamic, biological, and right ventricular functional changes following intraatrial shunt repair in patients with flow-induced pulmonary hypertension.

Atrial septal defects may result in pulmonary hypertension and right heart remodeling. We analyzed improvements in patients with flow-induced pulmonary hypertension and the activation of endothelial progenitor cells after flow reduction.

Recurrent cutaneous decompression illness after PFO device implantation: a case report.

It is well known that patency of the foramen ovale (PFO) is a risk factor for decompression illness (DCI) in scuba divers, even if they adhere to the currently accepted and used decompression tables (termed "an undeserved hit"). The correction of the PFO through percutaneous closure after DCI is an ongoing discussion. We describe a case of a diver who redeveloped a cutaneous DCI due to a recurrent PFO after initial treatment with an occluder device four years earlier.

Midterm Follow-up of Ureteral Embolization Using Vascular Plugs and N-Butyl Cyanoacrylate Glue.

This is a retrospective study of 9 consecutive female patients who underwent ureteral embolization via a "sandwich" technique with two vascular plugs and N-butyl cyanoacrylate glue for ureteral fistulae unresponsive to urinary diversion. Average age was 61 years (range, 39-77 y), average duration of diversion was 48 days (range, 2-120 d), and average follow-up was 11 months (range, 4-23 mo). Seven patients (78%) experienced immediate resolution of urinary leakage, and the other 2 (22%) required unilateral repeat treatment for resolution of leakage. Symptom resolution lasted throughout the follow-up period for all patients. Bilateral internal iliac artery pseudoaneurysms developed in 1 patient and were treated with embolization and stent placement.

Silent early migration of a Figulla® septal occluder into the left ventricle.

Comparison on the efficacy and safety of different occlusion devices for the treatment of patients with patent foramen ovale.