Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design.

Abstract To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability.
PMID
Related Publications

Elapsed time for capsular apposition to intraocular lens after cataract surgery.

Clinical performance of Alcon SA30AL and SA60AT single-piece acrylic intraocular lenses.

Effect of haptic material and number of intraocular lens on anterior capsule contraction after cataract surgery.

Anterior capsule opacification: correlation of pathologic findings with clinical sequelae.

Intraocular lens factors that may affect anterior capsule contraction.

Authors

Mayor MeshTerms

Acrylic Resins

Lenses, Intraocular

Keywords

Anterior lens capsule

Haptic

Intraocular lenses

Journal Title korean journal of ophthalmology : kjo
Publication Year Start




PMID- 28243021
OWN - NLM
STAT- MEDLINE
DA  - 20170228
DCOM- 20170314
LR  - 20170314
IS  - 2092-9382 (Electronic)
IS  - 1011-8942 (Linking)
VI  - 31
IP  - 1
DP  - 2017 Feb
TI  - Comparison of Anterior Capsule Stability Following Implantation of Three Single
      Piece Acrylic Intraocular Lenses with Different Haptic Design.
PG  - 32-38
LID - 10.3341/kjo.2017.31.1.32 [doi]
AB  - PURPOSE: To compare the anterior capsule contraction and intraocular lens (IOL)
      decentration among three types of IOL to determine the influence of haptic design
      on anterior capsule stability. METHODS: One hundred fifty patients were enrolled 
      in this prospective, randomized study and 260 eyes underwent implantation of one 
      of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic IOL (n =
      97), or a plate-haptic IOL (n = 89). The area of the anterior capsule opening,
      IOL decentration, and capsule overlap were measured using retroillumination
      photospot 1 day and 2 months after cataract surgery. RESULTS: The area of capsule
      opening at postoperative day 1 was significantly different between the three IOLs
      (p < 0.01). All IOLs showed reduction of the anterior capsule opening from 1 day 
      to 2 months after surgery, and greater reduction was shown in the modified
      C-haptic IOL (p < 0.001). At postoperative month 2, IOL decentration was
      significantly different between the IOLs and showed a positive correlation with
      the mean area reduction during month 2. CONCLUSIONS: The degree of anterior
      capsule contraction and IOL decentration in modified L-haptic IOLs were less than
      those in modified C-haptic IOLs and comparable to those in plate-haptic IOLs.
FAU - Yang, Soonwon
AU  - Yang S
AD  - Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital,
      College of Medicine, The Catholic University of Korea, Seoul, Korea.
FAU - Lim, Sung A
AU  - Lim SA
AD  - Nune Eye Hospital, Seoul, Korea.
FAU - Na, Kyung-Sun
AU  - Na KS
AD  - Department of Ophthalmology and Visual Science, Yeouido St. Mary's Hospital,
      College of Medicine, The Catholic University of Korea, Seoul, Korea.
FAU - Joo, Choun-Ki
AU  - Joo CK
AD  - Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital,
      College of Medicine, The Catholic University of Korea, Seoul, Korea.; Catholic
      Institute for Visual Science, College of Medicine, The Catholic University of
      Korea, Seoul, Korea.
LA  - eng
PT  - Journal Article
PT  - Randomized Controlled Trial
DEP - 20170202
PL  - Korea (South)
TA  - Korean J Ophthalmol
JT  - Korean journal of ophthalmology : KJO
JID - 8804513
RN  - 0 (Acrylic Resins)
RN  - 0 (Silicone Elastomers)
SB  - IM
MH  - *Acrylic Resins
MH  - Aged
MH  - Aphakia, Postcataract/physiopathology/*surgery
MH  - Female
MH  - Humans
MH  - *Lenses, Intraocular
MH  - Male
MH  - Middle Aged
MH  - Phacoemulsification/*methods
MH  - Prospective Studies
MH  - Prosthesis Design
MH  - Silicone Elastomers
MH  - Visual Acuity
PMC - PMC5327172
OTO - NOTNLM
OT  - *Anterior lens capsule
OT  - *Haptic
OT  - *Intraocular lenses
COI - Conflict of Interest: No potential conflict of interest relevant to this article 
      was reported.
EDAT- 2017/03/01 06:00
MHDA- 2017/03/16 06:00
CRDT- 2017/03/01 06:00
PHST- 2016/07/25 [received]
PHST- 2016/09/28 [accepted]
AID - 10.3341/kjo.2017.31.1.32 [doi]
PST - ppublish
SO  - Korean J Ophthalmol. 2017 Feb;31(1):32-38. doi: 10.3341/kjo.2017.31.1.32. Epub
      2017 Feb 2.

<?xml version="1.0" encoding="UTF-8"?>
<b:Sources SelectedStyle="" xmlns:b="http://schemas.openxmlformats.org/officeDocument/2006/bibliography"  xmlns="http://schemas.openxmlformats.org/officeDocument/2006/bibliography" >
</b:Sources>